Kyoritsu Test Equipment from the Test Equipment Shop
Since it's founding in 1940, Kyoritsu has made customer satisfaction and providing high quality products and services it's top priorities. Kyoritsu started early an effort to establish a system that ensures traceability to the national standards in order to produce reliable instruments as well as instruments that can assure reliability of other equipment and installations. When traceability is in place, measurements taken with an instrument any time and anywhere in any situation can be related to the appropriate national measurement standards through a clear and unbroken chain of comparisons.
Test Equipment shop carries a wide variety of different Kyoritsu equipment:
Kyoritsu Clamp Meters
Some features Kyoritsu clamp meters offer:
- Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
- CAT.IV Clamp Meters can measure the Voltage and Current in both very low and high power circuits.
- Thus, very useful for power distribution companies, power utilities and maintenance fields.
- Red LED, as "Non Contact Voltage" function, gives warning to the user on the presence of AC Voltage.
- Double molding gives comfortable feeling in palm.
- 6039 counts with Bar Graph display.
- MIN/MAX function enables to keep easily min & max value during measurement.

Kyoritsu Multimeters
Some features Kyoritsu multimeters offer:
- Innovative Multhimeters with current measurements up to 120A AC/DC
- Unique Open Jaw technology for AC/DC current measurements
- Very compact and as reliable as a tradictional full size multimeter

Kyoritsu Insulation Testers
Some features Kyoritsu insulation testers offer:
- 4 test voltages plus AC voltage range.
- Colour coded scales and range switch position for easy reading.
- Test leads with remote control switch.
- New robust housing case.
- Back light function.
- Neck strap for both hand's operation.

Kyoritsu Multifunction Testers
Some features Kyoritsu multifunction testers offer:
- Continuity: 20/200Ω 200mA Test Current
- Insulation: 500/1000V, 20/200MΩ 1mA Rated Test Current
- Loop Impedance: 20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)
- RCD: 10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
- Test of a large kind of RCD's: Standard, Selective, AC and A (DC sensitive breakers)
- Uc(Contact Voltage): 100V
- Designed to IEC 61010-1, IEC 61557
- Data Memory:300 measured results
- The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

Kyoritsu Earth Testers
Some features Kyoritsu earth testers offer:
- The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
- Dust and drip proof. (designed to IEC 529 IP54)
- Earth resistance value can be read directly from the scale.
- Designed to meet IEC 61010-1 safety standard.
- Capable of measuring earth voltage.
- Small and lightweight. Shock resistant new case material.
- 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
- Lead wire connection to C and P terminals and proper auxiliary earth resistance can be checked by "OK" lamp. Lead wire connection to C and E terminals is good when "OK" lamp is illuminated.

Kyoritsu Loop / PSC Testers
Some features Kyoritsu loop / PSC testers offer:
- Custom microprocessor controlled for highest accuracy and reliability.
- 3 LEDs for checking correct wiring status.
- 15mA LOOP measurement: LOOP impedance 2000Ω range measurement is carried out with low test current (15mA). The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).
- Direct reading of Prospective Short Circuit Current (PSC). (4118A only)
- Safe voltage measurement function.
- Large custom digital display readout on all models.
- Measure low loop resistances(resolution of 0.01Ω)
- Automatic lock-out if test resister overheats.
- Large custom digital display readout .
- Visual indication of reversed phase and neutral wiring at socket.
- Designed to IP54 Rating
- Complies with IEC 61557

Kyoritsu Meters and Power Analyzers
Some features Kyoritsu meters and power analyzers offer:
- Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured.
- 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis.
- One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory.
- Direct communication with PC via USB cable 6310 CE
- Built-in Input / Output Function of external signal enables the signal transmission to alarms.
- 2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function.
- Pull / Insert of CF card possible whenever on recording under the function of memory backup device.
- Can monitor insulation at leakage current by using optional leak clamp sensors.
- Built-in Print Screen Function enables to record display screen (Records 512 screens by using CF card: 1 screen 40KB).
- Can display Waveform and Vector, and can confirm the wiring connection, too.
- Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V.

|