SPECIFICATIONS
|
|
DC Voltage Ranges:
|
200 mV, 2 V, 20 V, 200 V, 600 V
|
|
DC Voltage Accuracy:
|
all ranges: ± (1 % rdg + 1 dgt)
|
|
DC Voltage Resolution:
|
100 μV
|
|
DC Voltage Input Impedance:
|
10 MΩ
|
|
AC Voltage (45 Hz to 500 Hz) Ranges:
|
200 mV, 2 V, 20 V, 200 V, 600 V
|
|
AC Voltage (45 Hz to 500 Hz) Accuracy:
|
all ranges: ± (1.5 % rdg + 4 dgts)
|
|
AC Voltage (45 Hz to 500 Hz) Input Impedance:
|
10 MΩ
|
|
AC Voltage (45 Hz to 500 Hz) Resolution:
|
100 μV
|
|
DC Current Ranges:
|
200 μA, 2 mA, 20 mA, 200 mA, 10 A
|
|
DC Current Accuracy:
|
200 μA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
|
|
DC Current Accuracy:
|
10 A range: ± (2.0 % rdg + 3 dgts)
|
|
DC Current Resolution:
|
0.1 μA
|
|
DC Current Voltage Burden (Max):
|
200 μA range: 1 mV/μA
|
|
DC Current Voltage Burden (Max):
|
|
2 mA range: 100 mV/1mA
|
|
DC Current Voltage Burden (Max):
|
20 mA range: 13 mV/1 mA
|
|
DC Current Voltage Burden (Max):
|
200 mA range: 4.6 mV/1 mA
|
|
DC Current Voltage Burden (Max):
|
10A range: 40 mV/1 A
|
|
AC Current (45 Hz to 500 Hz) Ranges:
|
200 μA, 2 mA, 20 mA, 200 mA, 10 A
|
|
AC Current (45 Hz to 500 Hz) Accuracy:
|
200 μA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
|
|
AC Current (45 Hz to 500 Hz) Accuracy:
|
10A range: ± (2.5 % rdg + 4 dgts)
|
|
AC Current (45 Hz to 500 kHz) Resolution:
|
0.1 μA
|
|
AC Current (45 Hz to 500 Hz) Voltage Burden:
|
See DC Current
|
|
Non-Contact Voltage Detector (NCV) AC Volts:
|
70 to 600 V ac
|
|
Non-Contact Voltage Detector (NCV):
|
Red LED and Audible Indicator
|