Fluke 117 multimeter
- 0.5% accuracy
- TRMS AC/DC Volts/Amps
- Min/Max/Average
- Cat III 600V
- Low Z (helps prevent false readings due to ghost voltage)
- Resistance, continuity, frequency and capacitance
- AutoVolt automatic ac/dc voltage selection
- non-contact voltage detection
Description
Fluke 117 This multimeter was designed by fluke in consultation with electricians in the field. Rated to 600V CAT III and incorporating the Fluke VoltAlertTM technology giving non contact voltage detection it is the perfect instrument for the commercial or domestic electrician.
The Fluke 117 has dual impedance capability: incorporating both regular high impedance test capabilities and low impedance functions for detecting ghost voltages, just switch to the Auto-V/LoZ (low impedance) test setting to whether measurement is a ghost voltage.
Auto-V stands for automatic volts. This feature automatically determines whether the measured signal is ac voltage or dc voltage, selects the correct function and range, and displays the correct information.
LoZ stands for Low Impedance (Z). This feature presents a low impedance input to the circuit under test. This reduces the possibility of false readings due to ghost voltages and improves accuracy when testing to determine absence or presence of voltage.
The Fluke 117 also includes the built-in VoltAlert non-contact voltage function. Located on the top of the meter above the LCD display, it’s another feature handy for detecting the invisible. The VoltAlert function detects the presence of ac voltage, sounds an audible tone and activates a red LED indicator light on the top center of the LCD display. Using this feature before making a contact measurement can add an extra layer of safety.
Buy the combo kit and save 29% Fluke 117/322 combo kit: pairs the new Fluke 117 DMM with a Fluke 322 clamp meter for productive and effective troubleshooting in one total solution, including the new C115 durable soft carrying case for protection and easy meter transportation.
Fluke 117 - True-RMS digital multimeter with non-contact voltage detection
Fluke 322 - Compact clamp meter
TPak - Magnetic Meter Hanging Strap
C115 - Deluxe soft carrying case with shoulder strap
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:
6.000 V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.0 V / 0.1 V
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:
600 Ω
Resolution:
1 Ω
Accuracy:
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:
600.0 ohm / 0.1 ohm
Range/Resolution:
6.000 ohm / 0.001 ohm
Range/Resolution:
60.00 k ohm / 0.01 k ohm
Range/Resolution:
600.0 k ohm / 0.1 k ohm
Range/Resolution:
6.000 M ohm / 0.001 M ohm
Accuracy:
0.9 % + 1
Range/Resolution:
40.00 M ohm / 0.01 M ohm
Accuracy:
5 % + 2
Diode Test
Range/Resolution:
2.000 V / 0.001 V
Accuracy:
0.9% + 2
Capacitance
Range/Resolution:
1000 nF / 1 nF
Range/Resolution:
10.00 μF / 0.01 μF
Range/Resolution:
100.0 μF / 0.1 μF
Range/Resolution:
9999 μF / 1 μF
Range/Resolution:
100 μF to 1000 μF
Accuracy:
1.9% + 2
Range/Resolution:
> 1000 μF
Accuracy:
5% + 20%
LoZ capacitance
Range:
1 nF to 500 μF
Accuracy:
10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution:
6.000 A / 0.001 A
Range/Resolution:
10.00 A / 0.01 A
Accuracy:
1.5% + 3
20 A continuous overload for 30 seconds max
DC amps
Range/Resolution:
6.000 A / 0.001 A
Range/Resolution:
10.00 A / 0.01 A
Accuracy:
1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution:
99.99 Hz / 0.01 Hz
Range/Resolution:
999.99 Hz / 0.1 Hz
Range/Resolution:
9.999 Hz / 0.001 Hz
Range/Resolution:
50.00 Hz / 0.01 Hz
Accuracy:
0.1% + 2
Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.