Description
Our Best Multimeter. - Now with Zoom Capabilities!
New diagnostic functionality for maximizing productivity in the plant. The new Fluke 289 True-RMS Industrial Logging Multimeter with TrendCapture is the next generation high performance industrial logging multimeter designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment.
With the ability to log data and review it graphically on-screen, you can solve problems faster and help minimize downtime. Let the new 289 be your watchdog for systems or processes while you are off solving other problems.
WATCH Demos via YOU TUBE! Just click the following links below:
VIDEO 1 VIDEO 2

APPLICATIONS:
- Develop, install, or maintain electronic devices
- Precision testing of surface mount and high density circuits
- Customers who need to log and record results to solve intermittent problems
- Communication; wireless, wired, LAN, broadband, CATV, audio/video
- Industrial / Electrical equipment
- Instrumentation (example: test and medical equipment)
- Consumer electronics
- Automotive
- Education
- Security

What's Included?
Supplemental Material:
- Registration Card
- Cal Practices Document
- CD-ROM Users' Manual (16 languages)
- Getting Started Manual
- Calibration Certification Sheet
Specs relating to Fluke 289 Multimeter
| Voltage DC |
| Accuracy |
0.025 % |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Voltage AC |
| Accuracy |
0.4 %(true-rms) |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Current DC |
| Accuracy |
0.06 % |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Current AC |
| Accuracy |
0.6%(true-rms) |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Temperature (excluding probe) |
| Accuracy |
1.0 % |
| Range and Resolution |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
|
| Resistance |
| Accuracy |
0.05 % |
| Range and Resolution |
500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
|
| Capacitance |
| Accuracy |
1.0 % |
| Range and Resolution |
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF |
|
| Frequency |
| Accuracy |
0.005% + 5 |
| Range and Resolution |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
|
| Additional functions/features |
| Multiple on-screen displays |
Yes |
| True-rms AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| Conductance |
50.00nS |
| Continuity beeper |
Yes |
| Battery/Fuse access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse time clock |
Yes |
| Time of day clock |
Yes |
| Min-Max-Avg |
Yes |
| Duty Cycle |
0.01 % to 99.99 % |
| Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Hold |
Yes |
| Isolated Optical Interface |
Yes |
| Auto/Touch Hold |
Yes |
| Reading memory |
Yes |
| Log to PC |
Yes |
| Interval/Event Logging |
Yes |
| Logging Memory |
Up to 10,000 readings |
|
To Download Data Sheet Click Here
|